Home > Products

High Voltage Electrial Partial Discharge Testers

  • RF08 Mini Series-modular Get Price!

    Service cart for SF6-gas handling of small to medium size gas-insulated equipment.

  • RF051 Economy Series SF6 Gas Handling Cart Get Price!

    For easy maintenance on high voltage switchgear Less than 220kv

  • RF391 Mega Series SF6 Gas Handling Unit Get Price!

    Maintenance device for large and extra large gas compartments.

  • RF300 SF6 Gas Purification for re-use System Get Price!

    SF6 recycling and re-use

  • S100 Micro Series SF6 Gas Recycling Device Get Price!

    Special application Recovery of a small amount of sf6 gas in a small SF6 Gas compartments.

  • RFJ SF6 Refilling Evacuating Devices Get Price!

    SF6 Gas Cylinder to Gas compartments

  • RA912 SF6 Gas Analyzer Get Price!

    For determining the quality of SF6 gas.he RA912 multi-functional analyzer allows the determination of up to seis quality parameters with only one measurement:SF6 concentration (%).Moisture concentration.SO2 concentration (ppmv).CO concentration (ppmv).H2S concentration (ppmv).Option: HF concentration (ppmv)

  • NA1013 SF6 Gas Monitoring System Get Price!

    For continuous monitoring of the SF6 quality.NA-1013 online infrared gas transmitter is base on the internet of things’s air quality monitoring instruments .It used online monitoring for toxic gases, SF6 gas, O2, temperature, humidity, etc. Fast response, high accuracy, with a variety of selectable signal output mode.Passed through the third grade EMC industry test. Compliance with IEEE 802.15.4 wireless communication standard, ZigBee communication protocol support

  • Smart SF6 Sensor Get Price!

    NDIR SF6 Sensor 10 years life for SF6 Gas Leakage detection.Measurement principle: Dual wavelength, Non Dispersive Infra-Red (NDIR).Measurement range: 0-50/1000/1500ppm.Gas supply: by diffusion (atmospheric pressure).Warm-up time: < 2 minutes (start-up time).< 11 minutes (fade in finished).< 30 minutes (full specification).Measuring response.Response time (t90): appr. 60 s.Digital resolution (@ zero): 1 ppm.Repeatability: ≤ ± 15 ppm.

  • I. Application: This equipment is mainly used under ≤50KV test voltage for power products such as transformers, power transformers, high voltage circuit breakers, cables accessories, products for power frequency voltage withstand test and partial discharge test and research pilot.II. Working Cond
    • Test Meters | Discount Electrical Test Equipment.Get Price!

      Latest News. NEW FLIR Screen-EST™ Skin-Temperature-Screening Software. The FLIR Screen-EST™ Skin-Temperature-Screening Software is a newly developed, plug-and-play, turnkey solution specifically designed to detect elevated skin temperature which can be indicative of a fever, a common symptom of many illnesses including COVID-19. This desktop software is easy to use and set up; it is.Contact Us · Electrical & Electronic · Tools & Accessories · Delivery · Gas, HVAC & Plumbing

    • High Voltage Testing | Low Frequency Constant DC High.Get Price!

      3/15/2020· For this test the power frequency high voltage is applied to the specimen or equipment under test for a long specific period to ensure the continuous high voltage withstanding capability of the device. N. B. : The transformer used for producing extra high voltage in this type of high voltage testing procedure, may not be of high power rating.

    • Medium and High Voltage Electrical Equipment Testing Get Price!

      4/27/2009· Cliff described some advances to their partial discharge (PD) testing and monitoring services that have expanded to include switchgear. Now, for those not steeped in an electrical engineering background, partial discharges are small electrical sparks that occur within a cable’s insulation, or on the surface of the insulation of medium and.

    • What is HIPOT Testing (Dielectric Strength Test)?Get Price!

      12/16/2019· Therefore, if we use dc test voltage, we ensure that the dc test voltage is under root 2 (or 1.414) times the ac test voltage, so the value of the dc voltage is equal to the ac voltage peaks. For example, for a 1500-V-ac voltage, the equivalent dc voltage to produce the same amount of stress on the insulation would be 1500 x 1.414 or 2121 V dc.

    • VLF Cable Test Voltage IEEE Standard | High Voltage IncGet Price!

      Once partial discharge is triggered in a defect under the test voltage, enough time must be allowed to permit the PD to create an electrical tree and grow to failure. The test voltage and time duration are both critical to causing failures at defect locations severe enough to be triggered into PD during the test.

    • The Basics of VLF Testing | HV TECHNOLOGIES, Inc.Get Price!

      Very low frequency (VLF) withstand testing is the application of an AC sinusoidal waveform, generally at 0.01 – 0.1 Hz, to assess the quality of electrical insulation in high capacitive loads, such as cables. During the test cables are subjected to a test voltage significantly higher than what they experience during normal operating conditions.




    Email: [email protected]

    Send your Inquiry

    Inquiry

    Using our contact forms you can also send inquiries, give feedback, request information and ask questions.
    Email:
    [email protected]