Home > Products

Moveable Sf6 Vacuum Pumping and Filling Device

  • RF08 Mini Series-modular Get Price!

    Service cart for SF6-gas handling of small to medium size gas-insulated equipment.

  • RF051 Economy Series SF6 Gas Handling Cart Get Price!

    For easy maintenance on high voltage switchgear Less than 220kv

  • RF391 Mega Series SF6 Gas Handling Unit Get Price!

    Maintenance device for large and extra large gas compartments.

  • RF300 SF6 Gas Purification for re-use System Get Price!

    SF6 recycling and re-use

  • S100 Micro Series SF6 Gas Recycling Device Get Price!

    Special application Recovery of a small amount of sf6 gas in a small SF6 Gas compartments.

  • RFJ SF6 Refilling Evacuating Devices Get Price!

    SF6 Gas Cylinder to Gas compartments

  • RA912 SF6 Gas Analyzer Get Price!

    For determining the quality of SF6 gas.he RA912 multi-functional analyzer allows the determination of up to seis quality parameters with only one measurement:SF6 concentration (%).Moisture concentration.SO2 concentration (ppmv).CO concentration (ppmv).H2S concentration (ppmv).Option: HF concentration (ppmv)

  • NA1013 SF6 Gas Monitoring System Get Price!

    For continuous monitoring of the SF6 quality.NA-1013 online infrared gas transmitter is base on the internet of things’s air quality monitoring instruments .It used online monitoring for toxic gases, SF6 gas, O2, temperature, humidity, etc. Fast response, high accuracy, with a variety of selectable signal output mode.Passed through the third grade EMC industry test. Compliance with IEEE 802.15.4 wireless communication standard, ZigBee communication protocol support

  • Smart SF6 Sensor Get Price!

    NDIR SF6 Sensor 10 years life for SF6 Gas Leakage detection.Measurement principle: Dual wavelength, Non Dispersive Infra-Red (NDIR).Measurement range: 0-50/1000/1500ppm.Gas supply: by diffusion (atmospheric pressure).Warm-up time: < 2 minutes (start-up time).< 11 minutes (fade in finished).< 30 minutes (full specification).Measuring response.Response time (t90): appr. 60 s.Digital resolution (@ zero): 1 ppm.Repeatability: ≤ ± 15 ppm.

  • Product Description:HZCQ-516Series vacuum pumping and inflation device is mainly used for vacuum pumping and vacuum degree determining of magnetic pole SF6 circuit breaker, transformer and other SF6 electric appliances when installation, operation and maintenance. The entire SF6 gas inflation and va
    • China Sf6 Gas Filling Equipment, Sf6 Gas Filling Equipment.Get Price!

      Sourcing Guide for Sf6 Gas Filling Equipment: A complete one stop sourcing platform for packaging & printing suppliers, manufacturers and factories, we are big enough to be able to offer an expanded product line of labels and packaging design capabilities yet small enough to be able to provide the personal service that is still so very important in business today.

    • China Measuring And Filling Device, Measuring And Filling.Get Price!

      Sourcing Guide for Measuring And Filling Device: A complete one stop sourcing platform for packaging & printing suppliers, manufacturers and factories, we are big enough to be able to offer an expanded product line of labels and packaging design capabilities yet small enough to be able to provide the personal service that is still so very important in business today.

    • Vacuum leak detection equipmentGet Price!

      Vacuum pumping of the true empty box and the vacuum pumping of the workpiece shall be carried out simultaneously; 3, open the door: sliding door, box type; 4, with clear helium function; 5. With SF6 moisture analysis function, it can effectively monitor the moisture content of gas. 6.

    • US9702814B2 - Systems and methods of infrared Get Price!

      An infrared detection device can be used to detect coal mine polar gas. The detection device can include a central processor and a gas pool assembly having a moveable optical window. The moveable optical window can include a stationary pool body and a moveable pool body inserted into the

    • 47563543 EPRI Inspection and Maintenance Guidelines for.Get Price!

      SF6 Two Pressure Circuit Breaker Maintenance Mechanical. 4.7.1. SF6 two pressure breakers are no longer made, due to the complexity of compressor and blast valve systems, compared with single pressure breakers. This type of breaker was only made for transmission voltages. They were made primarily as dead tank breakers, but also as live tank.

    • IPAC'10 - List of Keywords (vacuum)Get Price!

      660 行· The charge exchange device for 3GeV RCS in J-PARC, which require that a broken foil is PAPERTITLEOTHER KEYWORDSPAGEMOZRA02Trends in the Development of Insertion Devices for a Fuundulator, FEL, perman50MOPEA014DNA Double-Strand Break Induction in A549 Cells with proton, laser, target, ion91MOPEA017Developing of a C-Band 9 MeV / 6 MeV SW Electron Linelectron, linac, cavity, i100MOPEA031Application of Liquid Cluster Ion Beams in Surface Procion, acceleration, electr133查看accelconf.web.cern.ch的所有660行




    Email: [email protected]

    Send your Inquiry

    Inquiry

    Using our contact forms you can also send inquiries, give feedback, request information and ask questions.
    Email:
    [email protected]