Home > Products

Partial Discharge High Voltage Testing Equipment

  • RF08 Mini Series-modular Get Price!

    Service cart for SF6-gas handling of small to medium size gas-insulated equipment.

  • RF051 Economy Series SF6 Gas Handling Cart Get Price!

    For easy maintenance on high voltage switchgear Less than 220kv

  • RF391 Mega Series SF6 Gas Handling Unit Get Price!

    Maintenance device for large and extra large gas compartments.

  • RF300 SF6 Gas Purification for re-use System Get Price!

    SF6 recycling and re-use

  • S100 Micro Series SF6 Gas Recycling Device Get Price!

    Special application Recovery of a small amount of sf6 gas in a small SF6 Gas compartments.

  • RFJ SF6 Refilling Evacuating Devices Get Price!

    SF6 Gas Cylinder to Gas compartments

  • RA912 SF6 Gas Analyzer Get Price!

    For determining the quality of SF6 gas.he RA912 multi-functional analyzer allows the determination of up to seis quality parameters with only one measurement:SF6 concentration (%).Moisture concentration.SO2 concentration (ppmv).CO concentration (ppmv).H2S concentration (ppmv).Option: HF concentration (ppmv)

  • NA1013 SF6 Gas Monitoring System Get Price!

    For continuous monitoring of the SF6 quality.NA-1013 online infrared gas transmitter is base on the internet of things’s air quality monitoring instruments .It used online monitoring for toxic gases, SF6 gas, O2, temperature, humidity, etc. Fast response, high accuracy, with a variety of selectable signal output mode.Passed through the third grade EMC industry test. Compliance with IEEE 802.15.4 wireless communication standard, ZigBee communication protocol support

  • Smart SF6 Sensor Get Price!

    NDIR SF6 Sensor 10 years life for SF6 Gas Leakage detection.Measurement principle: Dual wavelength, Non Dispersive Infra-Red (NDIR).Measurement range: 0-50/1000/1500ppm.Gas supply: by diffusion (atmospheric pressure).Warm-up time: < 2 minutes (start-up time).< 11 minutes (fade in finished).< 30 minutes (full specification).Measuring response.Response time (t90): appr. 60 s.Digital resolution (@ zero): 1 ppm.Repeatability: ≤ ± 15 ppm.

  • partial discharge high voltage testing equipmentGeneral informationThe system is especially designed for testing GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS PT etc. It also can test transformers, power c
    • The Basics of Partial Discharge Testing | HV Get Price!

      What is Partial Discharge? When speaking of partial discharge, the most important standard that every expert will refer to is IEC 60270: High-voltage test techniques – Partial discharge measurements.This standard applies to the measurement of PD in electrical apparatus or systems when testing with AC voltage up to 400 Hz or with DC voltage.

    • Home - HVPDGet Price!

      Partial Discharge is a degenerative phenomenon that affects the electrical insulation of medium & high-voltage equipment. Partial discharge (PD) is the best early warning indicator of electrical insulation degredation in assets operating at 3.3 kV and above.Monitoring · Products and Services · Sensors · Training · Our Values · About Us

    • PARTIAL DISCHARGE TESTING (PD TESTING)Get Price!

      6/4/2019· Studies show that over 85% of disruptive failures in high voltage (HV) and medium voltage (MV) equipment are Partial Discharge related. Partial Discharge action ultimately leads to failure. Our PD testing service does not require shutdown and is the best way to plan maintenance, repair or replacement activities in a cost effective and efficient.

    • Partial Discharge Testing - High Voltage ServicesGet Price!

      Partial Discharge Testing Partial discharge occurs within layers of insulation of High Voltage equipment, it is a low level discharge that occurs within cables, joints, terminations, switchgear. Each discharge while at low level is crossing the air space gap present within

    • Partial discharge - WikipediaGet Price!

      Overview

    • Partial Discharges in Electrical InsulationGet Price!

      · PDF 文件What is Partial Discharge (PD) •PD only occurs where there is a gas (air, SF6, hydrogen) between the two conductors •The conductors must have a high voltage between them, creating an electric stress •If the electric stress in the gas exceeds 3 kV/mm of spacing (for most dry gases at 100 kPa), then electrons are stripped from the gas atoms

    • Partial Discharge Testing: What It Is and What It MeansGet Price!

      · PDF 文件sient voltage and continuous voltage ratings. In practice, testing to determine the inception voltage, and de-rating from the inception voltage by a factor related to transients determines the continuous rated voltage. PARTIAL DISCHARGE TESTING IN PRODUCTION Once the continuous rating is established, a convenient 100% production test is needed.

    • Cable partial discharge diagnostics | MeggerGet Price!

      Partial discharge test and monitoring systems can be supplied in the form of handheld tools, as well as bigger, transportable diagnostic products. Megger’s broad range of equipment – from battery operated online PD handheld units to full, extra high voltage (EHV) on-site testing systems – provides solutions for almost all types of MV and.